Search results for "External fixation"
showing 10 items of 14 documents
THE CHALLENGE OF OPEN TIBIAL SHAFT FRACTURES: WHEN TOMANAGE WITH EXTERNAL FIXATION AND WHEN TO USEINTRAMEDULLARY NAILING?
2020
Treatment of open tibial shaft fractures is challenging. External fixation (EF) is comparatively safe in treating these open injuries with the main advantages of easy application, minimal additional disruption, and convenient subsequent soft tissue repair. Tibial intramedullary nailing (IM) is optimal for the treatment of open tibial fractures. This study aims to report the outcomes of our multi-center experience in the management of open tibial shaft fractures, evaluating the efficacy and safety of using either the external fixation (EF) or intramedullary nailing (IM).In this study, clinical-radiographic results were evaluated in 26 cases of open fractures treated with an external fixator …
The challenge of open tibial shaft fractures: When tomanage with external fixation and when to useintramedullary nailing?
2020
Treatment of open tibial shaft fractures is challenging. External fixation (EF) is comparatively safe in treating these open injuries with the main advantages of easy application, minimal additional disruption, and convenient subsequent soft tissue repair. Tibial intramedullary nailing (IM) is optimal for the treatment of open tibial fractures. This study aims to report the outcomes of our multi-center experience in the management of open tibial shaft fractures, evaluating the efficacy and safety of using either the external fixation (EF) or intramedullary nailing (IM).In this study, clinical-radiographic results were evaluated in 26 cases of open fractures treated with an external fixator …
Clinical pathways for fragility fractures of the pelvic ring: personal experience and review of the literature
2014
AbstractFragility fractures of the pelvic ring (FFP) are increasing in frequency and require challenging treatment. A new comprehensive classification considers both fracture morphology and degree of instability. The classification system also provides recommendations for type and invasiveness of treatment. In this article, a literature review of treatment alternatives is presented and compared with our own experiences. Whereas FFP Type I lesions can be treated conservatively, FFP Types III and IV require surgical treatment. For FFP Type II lessions, percutaneous fixation techniques should be considered after a trial of conservative treatment. FFP Type III lesions need open reduction and in…
Indications and limitations of the fixator TGF “Gex-Fix” in proximal end humeral fractures
2014
Abstract The incidence of fractures of the humerus has increased exponentially in recent years. The most used classifications for humerus fracture are morphological (Neer), biological (AO/ASIF) and descriptive (Hertel). The types of surgical treatment for humerus fracture include prosthetic replacement and synthesis using different devices, including the Tension Guide Fixator (TGF), Gex-Fix. External fixation for displaced proximal humeral fractures avoids dissection and soft tissue stripping and has been reported by some authors to be associated with higher union rates, a lower incidence of avascular necrosis, less scarring of the scapulohumeral interface, and faster rehabilitation compare…
Supracondylar femoral fracture with an incidental enchondroma of the tibial plateau
2019
The enchondroma is a benign tumor of the endosteal cartilage and it is common in young-adult patients. These tumors are usually diagnosed when a pathologic fracture occurs at the site of the lesion or when they are accidentally discovered during investigations performed for other reasons. This report describes the case of a patient with an enchondroma of the external tibial plateau. Diagnosis was made treating an ipsilateral supracondylar femoral fracture caused by a traffic accident
Callus distraction of the femur and tibia. Experience with the Monofixator - indications for reosteosynthesis
1998
In a 4-year period, 18 patients underwent callus distraction of the femur or tibia with the use of a unilateral external fixator. Twelve patients had post-traumatic bone loss resulting from complex lower-limb fractures. The bony defect was located in the tibia in 11 cases and in the femur in one case. All patients had major associated soft-tissue lesions. The length of the bony defect averaged 6.25 cm. Eight fractures were infected at the beginning of treatment. Six other patients underwent callus distraction for reasons of limb shortening. Five femora and one tibia were lengthened. The average increase in length was 6.5 cm. There were no fixator-related complications during distraction. Th…
SUPRACONDYLAR FEMORAL FRACTURE WITH AN INCIDENTAL ENCHONDROMA OF THE TIBIAL PLATEAU
2019
The enchondroma is a benign tumor of the endosteal cartilage and it is common in young-adult patients. These tumors are usually diagnosed when a pathologic fracture occurs at the site of the lesion or when they are accidentally discovered during investigations performed for other reasons. This report describes the case of a patient with an enchondroma of the external tibial plateau. Diagnosis was made treating an ipsilateral supracondylar femoral fracture caused by a traffic accident.
Is there a role for percutaneous pelvic and acetabular reconstruction?
2007
The primary goal in the treatment of pelvic fractures is the restoration of haemodynamic stability. The secondary goal is the reconstruction of stability and symmetry of the pelvic ring. Percutaneous reconstruction can only be accepted if these goals are met. The type of definitive surgery is dependent of the degree of instability of the anterior and posterior pelvic ring. Retrograde transpubic screw fixation of pubic rami fractures is a good alternative to external fixation or plate and screw osteosynthesis. The technique of screw placement and image intensifier control is explained. Internal fixation of pure sacroiliac dislocations, fracture-dislocations of the sacroiliac joint and sacral…
Emergent and delayed hybrid external fixation management of tibial pilon fractures: A multicentric retrospective analysis of 80 patients
2017
Objective: To report our experience with the hybrid external fixator in emergency. Methods: We assessed 80 cases of pilon fracture treated with the external fixator during the period of January 2009 and December 2016:55 men (69%) and 30 women (33%) with a mean age of 40 years (range between 16 and 70). About 45 occurred as isolated trauma, 35 instead were politrauma. Each patient underwent standard radiographic examination and a CT examination. There were 28 open fractures (35%), (Gustilo type 1, 2 and 3) while closed fractures showed soft tissue involvement of various grade (2-3 Tscherne classification). In all cases, the external fixation, sometimes associated with other reduction and syn…
Microsurgery and external fixation in orthoplastic reconstruction of tibial injuries.
2019
"Orthoplastics" is a relatively new approach to lower limb reconstruction, where an integration of both plastic and orthopedic expertise is required, together with the availability of well-equipped facilities. Acute shortening and long-term frames for lengthening are generally considered alternatives to length preservation and soft tissue microsurgical reconstruction, but an integration of external fixation and reconstructive microsurgery is gaining an increasing role with refinements of joint approaches.Data on sixteen patients who underwent microsurgical lower limb reconstruction and external fixation with an orthoplastic approach, following acute or chronic tibial injury, were retrospect…